Fire extinguishing arrangement for paint and flammable liquid lockers on Marshall Islands flagged vessels Full-text PDF:TEC- 1318 (27kb) Contact:Material and Equipment Department Issued:26 Feb 2024 The Government of the Republic of Marshall Islands has noticed ClassNK of the special requirements for fire extinguishing arrangement for paint and flammable liquid lockers on Marshall Islands flagged vessels (Marine Notice No. 2-011-6 Rev. 2023). This Technical Information supersedes the previous ClassNK Technical Information No.TEC-0506 dated 10 March 2003. Depending on the area of the deck, paint and flammable liquid lockers should be provided with the following fire extinguishing system or portable fire extinguisher. 1. Existing vessels with keel laid before 1 February 1992 (1) Lockers of 10m2 or less in deck area – one portable fire extinguisher* should be located outside the entrance to the space. (2) Lockers greater than 10m2, but not greater